Specs at a glance
-
Sampling probe compatibility
Raman Rxn-10 probe
Field of application
Developed according to industry standards for single-use sensors, this Raman optic system is cGMP qualified and gamma sterilizable. The system is comprised of two parts - a reusable optic and a disposable fitting for single-use bioreactors (SUB). The Raman optic system for single use in conjunction with the Rxn-10 probe offers the same quality data as reusable Raman probes. This ability allows customers to develop products and processes without limitations of the final production reactor type.
Cell culture: glucose, lactate, amino acids, cell density, titer
Fermentation: glycerol, methanol, ethanol, sorbitol, biomass
Benefits
Disposable fitting for single-use bioreactors (SUB), plus a non-contact reusable optic
Developed to industry standards for single-use sensors
Gamma sterilizable
Tested and supplied by multiple SUB vendors
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Accessory Optics for the Rxn-10 Probe Technical Information
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN 31/05/202303/08/2022Language:
English
Version:
31/05/2023
File size:
467.9 KB
File name:
TI01635CEN_0322.pdf
-
-
-
Technical Information (TI)
Rxn-10 Raman Spectroscopic Probe Technical Information
System design and specifications
for the Raman Rxn-10 probeLanguage:
English
Version:
31/05/2023
File size:
423 KB
File name:
TI01629CEN_0322.pdf
-
-
-
Operating Instruction (BA)
Accessory optics for the Rxn-10 Probe Operating Instructions
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN 31/05/202303/08/2022Language:
English
Version:
31/05/2023
File size:
1.8 MB
File name:
BA02171CEN_0322.pdf
-
-
-
Operating Instruction (BA)
Rxn-10 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probeLanguage:
English
Version:
31/05/2023
File size:
1.2 MB
File name:
BA02160CEN_0322.pdf
-
-
-
Short Instruction (KA)
Rxn-10 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-10 probe
Language:
English
Version:
31/05/2023
File size:
895.3 KB
File name:
KA01546CEN_0322.pdf
-
-
-
Short Instruction (KA)
Accessory Optics for the Rxn-10 Probe Brief Operating Instructions
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN 31/05/202303/08/2022Language:
English
Version:
31/05/2023
File size:
1 MB
File name:
KA01551CEN_0322.pdf
-
-
-
PU (Publication)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Language:
English
Version:
19/04/2022
File size:
1.1 MB
File name:
PU01447CEN_0222.pdf
-
-
-
PU (Publication)
Endress+Hauser - your one-source Life Sciences technology partner
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).Language:
English
Version:
27/06/2024
File size:
1.9 MB
File name:
PU01585CEN_0124.pdf
-
-
-
PU (Publication)
Lab-to-process monitoring & control in Life Sciences - Reliable measurement of bioprocess physical and chemical properties
A combined product list of analysis offerings from both Optical Analysis
and LIquid Analysis for bioprocessing applications in the life science
industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, bio multi optic and bio sleeve, Raman flow assembly,
Rxn-45 probe, Rxn-46 probe, Raman optic system for single use,
Memosens CPS61E, Memosens COS81E, OUSBT66, Memosens CPS61E,
Memosens CPS77E, Memosens CLS82E, OUSAF44, Memosens CPS11E,
Memosens CLS16E, TOC Analyzer CA79, Liquiline transmitter platform, and
Memobase software).Language:
English
Version:
11/04/2024
File size:
776.1 KB
File name:
PU01484CEN_0224.pdf
-
-
-
PU (Publication)
Raman calibration and verification kits - Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).Language:
English
Version:
13/12/2023
File size:
2.1 MB
File name:
PU01518CEN_0223.pdf
-