Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec -
Measuring range
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Field of application
With its international approvals for custody transfer as well as drinking water, Promag W serves the broadest variety of applications. It is available as both compact or remote version. Promag W 400 saves time and costs thanks to the broad functionality of its transmitter optimized for Water & Wastewater. In addition, Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Ideal for water measurement , e.g. drinking water, utility water and industrial/municipal wastewater
Device properties
International drinking water approvals
Degree of protection IP68 (Type 6P enclosure)
Approved for custody transfer to MI-001/OIML R49
Transmitter housing made of durable polycarbonate or aluminium
WLAN access
Integrated data logger: measured values monitoring
Benefits
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss
Flexible engineering – sensor with fixed or lap-joint process connections
Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
Improved plant availability – sensor compliant with industry-specific requirements
Safe operation – no need to open the device
Time-saving local operation without additional software and hardware – integrated web server
Integrated verification and build-up detection – Heartbeat Technology
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Proline Promag W 400
English version - 09/2021
Electromagnetic flowmeter
EN 01/09/202101/01/202001/02/201901/10/201714/03/2017Language:
English
Version:
01/09/2021
File size:
5.4 MB
File name:
TI01046DEN_1021.pdf
-
-
-
Miscellaneous
Product family: CNGmass, Cubemass, Cubemass C, Dosimag, Dosimag OEM, Dosimass, Dosimass OEM, LNGmass, LPGmass, Magphant, Picomag, Pr omag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass A, Promass E, Promass F, Promass G, Promass H, Promass I, Promass K, Promass O, Promass P, Promass Q, Promass S, Promass U, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93 , Prosonic Flow B, Prosonic Flow E, Prosonic Flow G, PROSONIC FLOW I, Prosonic Flow P, Prosonic Flow W, Prowirl D, Prowirl F, Prowir l O, Prowirl R, t-mass A, t-mass B, t-mass F, t-mass I, t-mass T
Russian version - 06/2024
Product root: 55S-, 5BH-, 5CH-, 5DBB-, 5DH-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5HBB, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5PBB, 5RH-, 5SH-, 5W3B-, 5W4C-, 5W5B-, 5W8C-, 5WBB, 6AAB-, 6BAB-, 6F3B-, 6F5B-, 6I3B-, 6I5B-, 6TAB-, 7D2C-, 7F2C-, 7O2C-, 7R2C-, 8A1B-, 8A2B-, 8A3C-, 8A5C-, 8BE-, 8C1B-, 8C3B-, 8C5B-, 8CM-, 8CN-, 8DF-, 8E1C-, 8E2C-, 8E3B-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8F5B-, 8FE-, 8FF-, 8G1B- , 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8KBB-, 8O1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8PE-, 8Q3B-, 8Q5B-, 8RE-, 8S1C-, 8S3B-, 8S5B-, 8U5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93P-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9I4B-, 9P5B-, 9W4B-, D5AB-, D8AB-, D8CB-, D8EB-, D 8LB-, DMA-, DTI200- Region: Eurasian Economic Union Approval agency: EAC Approval number: EAC_KZ-7500533
Language:
Russian
Version:
01/06/2024
File size:
1.2 MB
File name:
KZ7500533-13-12-02449_Proline-all_ZE000.pdf
-
-
-
Technical Information (TI)
Proline Promag W 400
Electromagnetic flowmeter
EN 01/09/202101/01/202001/02/201901/10/201714/03/2017Language:
English
Version:
01/09/2021
File size:
5.4 MB
File name:
TI01046DEN_1021.pdf
-
-
-
Operating Instruction (BA)
Proline Promag W 400 PROFIBUS DP
Electromagnetic flowmeter
EN 01/02/202201/01/202001/02/201901/10/201701/03/2015Language:
English
Version:
01/02/2022
File size:
6.1 MB
File name:
BA01234DEN_0721-00.pdf
-
-
-
Operating Instruction (BA)
Proline Promag W 400 EtherNet/IP
Electromagnetic flowmeter
EN 01/02/202201/01/202001/02/201901/10/201701/03/2015Language:
English
Version:
01/02/2022
File size:
6.4 MB
File name:
BA01214DEN_0721-00.pdf
-
-
-
Operating Instruction (BA)
Proline Promag W 400 HART
Electromagnetic flowmeter
EN 01/09/202101/01/202001/02/201901/10/201714/03/2017Language:
English
Version:
01/09/2021
File size:
7 MB
File name:
BA01063DEN_0921.pdf
-
-
-
Operating Instruction (BA)
Proline Promag W 400 Modbus RS485
Electromagnetic flowmeter
EN 01/02/202201/01/202001/02/201901/10/201701/03/2015Language:
English
Version:
01/02/2022
File size:
6 MB
File name:
BA01231DEN_0621-00.pdf
-
-
-
Device Parameter (GP)
Proline Promag 400 HART
Electromagnetic flowmeter
EN 01/09/202114/03/201707/12/2015Language:
English
Version:
01/09/2021
File size:
2 MB
File name:
GP01043DEN_0321.pdf
-
-
-
Device Parameter (GP)
Proline Promag 400 EtherNet/IP
Electromagnetic flowmeter
EN 01/02/202223/12/2015Language:
English
Version:
01/02/2022
File size:
1.5 MB
File name:
GP01046DEN_0221-00.pdf
-
-
-
Device Parameter (GP)
Proline Promag 400 PROFIBUS DP
Electromagnetic flowmeter
EN 01/02/202223/12/2015Language:
English
Version:
01/02/2022
File size:
1.8 MB
File name:
GP01044DEN_0221-00.pdf
-
-
-
Device Parameter (GP)
Proline Promag 400 Modbus RS485
Electromagnetic flowmeter
EN 01/02/202223/12/2015Language:
English
Version:
01/02/2022
File size:
2 MB
File name:
GP01045DEN_0221-00.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 400
PROFIBUS DP transmitter
with electromagnetic sensorEN 01/02/202201/02/2019Language:
English
Version:
01/02/2022
File size:
3.4 MB
File name:
KA01420DEN_0221-00.pdf
-