Successor
Memosens sensor for drinking water, pool and process water as well as utilities in all industries
Read more
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Application
Ensuring reliable disinfection in drinking water Process water Dosing disinfectant efficiently in pool water Detect the absence or presence of free chlorine in Utilities Guarantee food safety and provide hygienic packaging and bottling
Characteristic
Amperometric measurement of dissolved free chlorine
Measuring range
Trace: 0 to 5 mg/l HOCl Standard: 0 to 20 mg/l HOCl High: 0 to 200 mg/l HOCl
Measuring method
Closed, membrane covered measuring cell Reduction of free chlorine at the cathode
Design
Closed amperometric 2-electrode measuring cell with PVDF membrane
Material
Sensor shaft: POM Membrane: PVDF Membrane cap: PVDF Sealing ring: FKM
Dimension
Diameter: 25 mm (0.98 inch) Length: 161 mm (6.34 inch)
Process temperature
0 to 55 °C (32 to 130 °F), non-freezing
Process pressure
Max. 1 bar (max. 14.5 psi)
Temperature sensor
10k NTC integrated (Memosens)
Connection
Inductive, digital connection head with Memosens
Most downloaded
CCS51D
English version - 07/2020
Digital sensor with Memosens technology for determining free chlorine
EN
BG CS DA DE EL ES ET FI FR HR HU ID IT JA KO LT LV NL NO PL PT RO RU SK SL SV TH TR ZH
20/07/2020
10/12/2019
20/09/2018
Language:
English
Version:
20/07/2020
File size:
1.4 MB
File name:
BA01906CEN_0320.pdf
183 documents
Memosens CCS51D
Technical Information
Digital sensor with Memosens technology for determining free chlorine
EN
German Spanish French Italian Japanese Polish Portuguese Romanian Russian Chinese
20/09/2018
Language:
English
Version:
20/09/2018
File size:
752.9 KB
File name:
TI01423CEN_0118.pdf
Digital sensor with Memosens technology for determining free chlorine
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Indonesian Italian Japanese Korean Lithuanian Latvian Dutch Norwegian Polish Portuguese Romanian Russian Slovak Slovenian Swedish Thai Turkish Chinese
20/07/2020
10/12/2019
20/09/2018
Language:
English
Version:
20/07/2020
File size:
1.4 MB
File name:
BA01906CEN_0320.pdf
Disinfection applications
Measuring ranges and suitable sensors
Language:
English
Version:
16/06/2023
File size:
603.1 KB
File name:
PU01405CEN-disinfection-sensor-application.pdf
Messbereiche und geeignete Sensoren
Language:
German
Version:
03/11/2023
File size:
678.7 KB
File name:
PU01405CDE_02.23_Desinfektionsanwendungen.pdf
Sensors, transmitters, compact devices and assemblies
Experts in Liquid Analysis
Language:
English
Version:
24/09/2024
File size:
4.2 MB
File name:
FA00007CEN_Analyse_21.24_LowRes.pdf
Kompetenz in der Flüssigkeitsanalyse
Vom Sensor bis zur schlüsselfertigen Komplettlösung
Language:
German
Version:
21/09/2022
File size:
1.3 MB
File name:
FA01018CDE_0422_Analyse_Portfolio_lowres.pdf
Sensörlerden komple anahtar teslim çözümlere
Language:
Turkish
Version:
23/11/2023
File size:
7.2 MB
File name:
FA01088C56TR01.23.pdf
Sensoren, Messumformer, Kompaktgeräte and Armaturen
Kompetenz in der Flüssigkeitsanalyse
Language:
German
Version:
24/09/2024
File size:
4.1 MB
File name:
FA00007CDE_Analyse_21.24_LowRes.pdf
Expertise in liquid analysis
From sensors to complete turnkey solutions
Language:
English
Version:
21/09/2022
File size:
1.2 MB
File name:
FA01018CEN_0422_Analysis_Portfolio_lowres.pdf
Aus Freude an gutem Wasser
Frische Ideen für Wasserwerke, Verteilernetze, Oberflächenwasser und Industrieanlagen
Language:
German
Version:
14/07/2023
File size:
2.1 MB
File name:
CP01335CDE_0223_Kompetenz in Wasser.pdf
For the love of quality water
Fresh ideas for waterworks, distribution networks, surface waters and industrial plants.
Language:
English
Version:
14/07/2023
File size:
2 MB
File name:
CP01335CEN_0223_Competence in water_LoRes.pdf
Une mesure de chlore libre pour le suivi de la désinfection de l’eau
Le Syndicat des Eaux de Basse-Vigneulles et Faulquemont fait confiance aux platines d’analyse d’Endress+Hauser
Language:
French
Version:
17/06/2021
File size:
358.2 KB
File name:
CS01658X-SEBVF-BD.pdf
Sauberes Wasser für Forschung und Mensch
Trinkwasserdesinfektion im Uniklinikum Würzburg
Language:
German
Version:
18/08/2021
File size:
723.7 KB
File name:
CS01718CDE_0122_Sauberes Wasser fuer Forschung und Mensch.pdf
Surveillance de l’eau potable lors de grandes manifestations
Une eau potable de qualité irréprochable doit être mise à disposition des 30'000 participants au camp scout BuLa. Grâce à la solution Netilion, le contrôle peut être effectué en temps et en heure, quel que soit le lieu.
Language:
French
Version:
04/04/2024
File size:
678.3 KB
File name:
CS01882S_20_FR_01_24_00_BULA_FR_.pdf
Free chlorine measurement for
monitoring water disinfection
Trusted analysis panels for drinking water
Language:
English
Version:
17/06/2021
File size:
500.8 KB
File name:
CS01658_Free chlorine measurement for monitoring water disinfection.pdf
Monitoraggio dell’acqua potabile per grandi eventi -
con il pannello di analisi e l’ecosistema Netilion basato su cloud
Sui 120 ettari del sito di Goms è stato necessario fornire acqua potabile di qualità impeccabile ai 30.000 partecipanti al campo scout. Il caldo insolito e il gran numero di visitatori hanno posto gli organizzatori di fronte a sfide particolari.
Language:
Italian
Version:
23/04/2024
File size:
1 MB
File name:
CS01887S_20_IT_01_24_00_BULA_IT_.pdf
Messung des freien Chlors zur
Überwachung der Wasserdesinfektion
Bewährte Analysepanels für Trinkwasser
Language:
German
Version:
17/06/2021
File size:
698.3 KB
File name:
CS01658_Messung des freien Chlors zur Ueberwachung der Trinkwasserdesinfektion.pdf
Safeguarding health with clean water
Disinfection and monitoring of drinking water
Language:
English
Version:
28/07/2022
File size:
734.9 KB
File name:
CS01718CEN_0122_Safeguarding health with clean water.pdf
Trinkwasser-Überwachung bei Grossveranstaltung
Für die 30’000 Teilnehmer des Pfadilagers im BuLa muss Trinkwasser in einwandfreier Qualität zur Verfügung gestellt werden. Mit der Netilion-Lösung kann die Kontrolle zeit- und ortsunabhängig erfolgen.
Language:
German
Version:
12/10/2022
File size:
833.5 KB
File name:
CS01708S20DE01.22_00_BULA_.pdf
Safe, efficient disinfection
Precise and long-term stable measurement of free chlorine with Memosens CCS51D
Language:
English
Version:
04/12/2018
File size:
651.6 KB
File name:
IN01132CEN_CCS51D_lowres.pdf
Désinfection efficace et sûre
Mesure précise et stable à long terme du chlore libre avec Memosens CCS51D
Language:
French
Version:
04/12/2018
File size:
569.1 KB
File name:
IN01132CFR_0118.pdf
Sichere, effektive Desinfektion
Präzise und langzeitstabile Messung von freiem Chlor mit Memosens CCS51D
Language:
German
Version:
17/12/2018
File size:
756.6 KB
File name:
IN01132CDE_CCS51D_lowres.pdf
Electrolyte for CCS50(D)/CCS51(D)
Language:
Turkish
Version:
17/10/2023
File size:
185.9 KB
File name:
MSDS_CCV05-50x_51x_(TR).pdf
Electrolyte for CCS50(D)/CCS51(D)
Language:
French
Version:
29/04/2022
File size:
42.9 KB
File name:
MSDS_CCV05-50x_51x_(F).pdf
Electrolyte for CCS50(D)/CCS51(D)
Language:
Estonian
Version:
29/04/2022
File size:
40.4 KB
File name:
MSDS_CCV05-50x_51x_(EST).pdf
Electrolyte for CCS50(D)/CCS51(D)
Language:
English
Version:
29/04/2022
File size:
40.1 KB
File name:
MSDS_CCV05-50x_51x_(M).pdf
CCV05-50x_51x (Belgium (Dutch))
Electrolyte for CCS50(D)/CCS51(D)
Language:
Dutch
Version:
29/04/2022
File size:
42.1 KB
File name:
MSDS_CCV05-50x_51x_(BNL).pdf
CCV05-50x_51x (Saudi Arabien)
Electrolyte for CCS50(D)/CCS51(D)
Language:
Arabic
Version:
29/04/2022
File size:
168.8 KB
File name:
MSDS_CCV05-50x_51x_(SAA).pdf
CCV05-50x_51x (European Union)
Electrolyte for CCS50(D)/CCS51(D)
Language:
English
Version:
29/04/2022
File size:
40.1 KB
File name:
MSDS_CCV05-50x_51x_(EU).pdf
Electrolyte for CCS50(D)/CCS51(D)
Language:
Japanese
Version:
29/04/2022
File size:
273.5 KB
File name:
MSDS_CCV05-50x_51x_(J).pdf
Search spare parts by number in drawing
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Drawing number
Order code
2
CCV05-
Kit adapter CCS5x(D/E) for CCA250
Kit adapter CCS5x(D/E) for CYA112
Kit adapter CCS5x(D/E) for CYA27+CCA151
Kit adapter CCS5x(D/E) for CYA27-xxxB
photometer M+N PF-3, disinfection
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all